2749.952749.952
Nonin LifeSense® Tabletop Capnograph/Pulse OximeterFast and Easy EtCO2 and SpO2 Monitoring
The Nonin Medical LifeSense® Tabletop Capnography and Pulse Oximetry Monitor offers proven PureSAT® SpO2 and Nonin sidestream EtCO2 technologies for a wide range of clinical settings for both intubated and non-intubated patients. Portable, accurate and cost-effective, LifeSense is perfect for monitoring in and outside the hospital setting. ...
NoninNonin LifeSense® Tabletop Capnograph/Pulse Oximete

Nonin LifeSense® Tabletop Capnograph/Pulse Oximeter

Fast and Easy EtCO2 and SpO2 Monitoring

Nonin LifeSense® Tabletop Capnograph/Pulse Oximete
LifeSense® Tabletop Capnograph/Pulse Oximete
Nonin LifeSense® Tabletop Capnograph/Pulse OximeteLifeSense® Tabletop Capnograph/Pulse Oximete
Select Item
Please Select
LifeSense w/ Adult Cuff, each
$2,749.95
LifeSense w/ Sm Adult Cuff, each
$2,749.95
Description

The Nonin Medical LifeSense® Tabletop Capnography and Pulse Oximetry Monitor offers proven PureSAT® SpO2 and Nonin sidestream EtCO2 technologies for a wide range of clinical settings for both intubated and non-intubated patients. Portable, accurate and cost-effective, LifeSense is perfect for monitoring in and outside the hospital setting. Choose from a full line of LifeSense-compatible Nonin PureLight® reusable and disposable pulse oximetry sensors for infants to adults.

Product Highlights:

  • Meets rigorous ISO requirements for EMS transport
  • WIDESCREEN touch-panel backlit LCD display
  • Nonin PureSAT SpO2 technology
  • Nonin sidestream EtCO2 technology
  • Numerical pulse rate and respiratory rate display
  • Numerical EtCO2 and SpO2 display
  • Four-hour trending of pulse rate, SpO2, respiration rate and EtCO2
  • Capnograph and plethysmograph display
  • Audible and visual alarms
  • Data output via RS-232 port
  • Full line of infant to adult SpO2 sensors (reusable and disposable)
  • Full range of infant to adult sampling lines
  • Carrying bag
  • Adjustable mounting clamp
  • TrendSense memory module, download cable and software
  • Sens DAC Digital to analog converter cables for pulse and capnography

Pulse Oximeter Specifications:

  • Displayed Oxygen Saturation Range (SpO2): 0 to 100 %
  • Displayed Pulse Rate Range: 18 to 255 BPM
  • Measurement Wavelengths*:
    • Red: 660 nanometers @ 0.8 mW max. average
    • Infrared: 910 nanometers @ 1.2 mW max. average

Accuracy - Sensors: Declared accuracy data for compatible sensors can be found in Nonin’s Sensor Accuracy document.

*This information is especially useful for clinicians performing photodynamic therapy.

SpO2 Accuracy Testing
SpO2 accuracy testing is conducted during induced hypoxia studies on healthy, non-smoking, light-to-dark-skinned subjects during motion and no-motion conditions in an independent research laboratory. The measured arterial hemoglobin saturation value (SpO2) of the sensors is compared to arterial hemoglobin oxygen (SaO2) value, determined from blood samples with a laboratory co-oximeter. The accuracy of the sensors in comparison to the co-oximeter samples measured over the SpO2 range of 70 - 100%. Accuracy data is calculated using the root-meansquared (Arms value) for all subjects, per ISO 80601-2-61, Standard Specification for Pulse Oximeters for Accuracy.

Capnography Specifications:

  • Respiration Range: 3 to 60 respirations/minute
  • Update Frequency: Once every breath (No Breath alarm after 25 seconds)
  • Respiration Accuracy:
    • 3 to 50 respirations/min ± 2
    • 51 to 60 respirations/min ± 3
  • EtCO2/CO2 Range: 0 to 9.9 kPa or 0 to 99 mmHg
  • EtCO2/CO2 Accuracy:
    • ±0.2 kPa / ±2 mmHg, +8% of reading†
    • 540 - 795 mmHg
    • (EtCO2/CO2 reading reaches its steady state accuracy 10 minutes after power up)

Update Frequency: Once every breath (No Breath alarm after 25 seconds)
Sampling Rate: 4 Hz (4 times per second)
Total System Response Time: 4 seconds (includes delay time and rise time)
Drift of Measurement: Within CO2 accuracy specifications for 6 hours of continuous monitoring
Measurement: Automatic barometric pressure compensation and CO2 temperature compensation

Return Policy

Shipping Terms:

 

Orders will be shipped via UPS Standard Ground unless other handling is requested or deemed more economical. Freight will be prepaid and added to the invoice. QuadMed will pay standard ground shipment costs on all orders over $150.00  for any shipment delivered in the U.S. except for Alaska and Hawaii.

 

Any orders under $150.00 will be charged a $14.95 handling fee for any shipment delivered in the U.S. except for Alaska and Hawaii. Orders going to Alaska or Hawaii actual shipping rates apply.  For all resellers, freight will be prepaid and added to the invoice. Shipments will be made to business addresses only.

 

 

International Orders:

 

There is a $1000.00 minimum for orders placed for delivery outside of the United States. International orders must prepay via wire transfer. Receipt of wire transfer is required before any shipments are made on the order. If the products ordered require a Medical Authorization letter, it must be submitted in English.

 

 

Returned Goods:

 

Written authorization must be obtained prior to returning merchandise. All returns should be sent within 30 days in resalable condition. Returns are subject to a 20% restocking charge. Merchandise held longer than 90 days, or custom items, are not returnable. All returned items must be sent prepaid.


All returns must be accompanied by an RMA. If you need to return an item or items, please contact Customer Service at 800-933-7334 or email us at [email protected] to obtain an RMA.

TEASoftware