The Airon MACS CPAP System is the next generation CPAP System for EMS ground and air transport. The MACS CPAP Systemworks with the patient, providing low spontaneous work of breathing compared to disposable CPAP mask options, and delivers a better patient experience with critical care delivery. MACS is built tough to stand up to EMS in-field rigor. In fact, MACS is rugged enough to withstand the tests required for the US Army Air Worthiness Certification*. These tests represent the harshest tests for any product.

MACS is designed for patient application by mask or endotracheal tube. CPAP application for those patients in respiratory distress - congestive heart failure (CHF), asthma, COPD or for any patient with severe breathing difficulty.MACS is an easy-to-use, economical mask CPAP (Continuous Positive Airway Pressure) system. Its demand flow system delivers CPAP without wasting oxygen.A calibrated knob sets the CPAP level and a switch selects 65% or 100% oxygen. Your per run cost is less due to lower oxygen costs and affordable patient circuits.MACS supports patients in respiratory distress who would otherwise require intubation.

The Airon MACS CPAP System Offers:

  • Provides non-invasive or invasive patient support
  • Low patient Work of Breathing (WOB) with peak flow of up to 140 L/min to meet patient needs
  • 100% or 65% to match patient oxygen requirements
  • Low-profile, easy-seal mask reduces facial pressure
  • All pneumatic design and built tough; no batteries required
  • Calibrated CPAP control allows easy pressure adjustment to match patient requirements
  • Demand flow system with automatic flow triggering; peak flow to 140 L/min
  • Oxygen use only as needed to match patient effort
  • Pressure displayed on night viewable manometer
  • Gas supply - 55 psi ± 15 psi oxygen 3.8 ± 1 bar)
  • Size - 3.5" W x 8" D x 6.75" H (9 cm x 20 cm x 17 cm)
  • Weight - 3 lbs. (1.35 kg)
  • Classification according to MDD 93/42/EEC: IIb
  • Meets international standards
  • ASTM F 920-85 Minimum Performance and Safety Requirements for Resuscitators Intended for use with Humans
  • ISO 10651-5:2006 Lung ventilators for medical use - Particular requirements for basic safety and essential performance
  • 5: Gas-powered emergency resuscitators
  • IEC 60529:2001 Degrees of protection provided by enclosures, level IPX4
  • CPAP: 0 to 20 cm H2O (mbar)
  • Oxygen: 100% or 65%
  • * Based on US Department of Defense Standard MIL-HDBK-516, October 2002

    MACS CPAP Startup Kit Includes: (1) MACS CPAP System, (1) DISS coiled high pressure oxygen hose, 15 foot (4.6m), green (ISO color hose available), (1) MACS Travel Bag, (1) Box of 58011 patient circuits – 6 foot (1.8m), (10) large adult mask / head strap, single patient use

    Airon MACS CPAP System

    $2,193.45
    -
    $2,683.45
    (0)
    Availability:
    Items that are In Stock typically ship same business day.
    Adding to cart… The item has been added

    To purchase this product a Medical Authorization Letter must be on file. You can fill one out HERE.

    SPECS

    • Classification according to MDD 93/42/EEC

      IIb
    • CPAP

      to 2 cm H2O (mbar)
    • Oxygen

      1% or 65%