85.9585.953Breathing \ CPAP Products

Flow-Safe II®+ Disposable BiLevel CPAP System

Flow-Safe II+ is the First Disposable BiLevel & CPAP System in ONE!

Now there is no need for expensive BiLevel capital equipment! Flow-Safe II®+ Disposable BiLevel CPAP System is the only available Disposable BiLevel CPAP system with integrated manometer for verifying pressures. The lightweight disposable feature allo
Mercury MedicalFlow-Safe II®+ Disposable BiLevel CPAP System

Flow-Safe II®+ Disposable BiLevel CPAP System

Flow-Safe II+ is the First Disposable BiLevel & CPAP System in ONE!

Flow-Safe II®+ Disposable BiLevel CPAP System
Flow-Safe II®+ Disposable BiLevel CPAP System (2)
Flow-Safe II®+ Disposable BiLevel CPAP System (3)
Flow-Safe II®+ Disposable BiLevel CPAP SystemFlow-Safe II®+ Disposable BiLevel CPAP System (2)Flow-Safe II®+ Disposable BiLevel CPAP System (3)
Select Item
Please Select
Large Adult, each
$85.95
Medium/Small Adult, each
$85.95
Small/Child, each
$85.95
Specifications
BrandMercury Medical
Description

Now there is no need for expensive BiLevel capital equipment!

Flow-Safe II®+ Disposable BiLevel CPAP System is the only available Disposable BiLevel CPAP system with integrated manometer for verifying pressures. The lightweight disposable feature allows for easy CPAP or BiLevel CPAP therapy set up and delivery during transport. Flow-Safe II+ is ideal for situations where backup BiLevel CPAP equipment is scarce or unavailable.

Everything clinicians need for delivering CPAP or BiLevel therapy is available in one Flow-Safe II®+ Disposable BiLevel CPAP System. This includes an adjustable deluxe full face mask, manometer for verifying CPAP and BiLevel iPAP and ePAP pressures. Ideal for transport and is easy to set-up - just attach the oxygen tubing to an oxygen source for delivering your choice of CPAP or BiLevel therapy.

Product Description:

  • The Mercury Medical Flow-Safe II ®+ device is a respiratory aid intended for use with a facemask or advanced airway and gas supplying device to elevate pressure in the patient’s lungs. The level of airway pressure delivered to the respiratory system may be set to increase during inspiration and decrease during expiration.

Connections:

  • Standard oxygen tubing nipple
  • Patient connection ISO 5356-1 - 15mm taper female and 22mm taper male

Indications for Use:

  • The Mercury Medical Flow-Safe II+ device is intended to provide CPAP or BiLevel CPAP pressures to spontaneously breathing patients in the hospital, surgery center and pre-hospital environment.

DIRECTIONS FOR PROVIDING CPAP:
Ensure device is set in CPAP mode-Green switch is set to CPAP

1. Connect O2 tubing nipple to gas source. Turn on gas source.
2. Secure the face mask snugly to patient’s face using head harness.
3. Slowly increase gas flow to 6 - 8 LPM. Check mask fit to patient and device connections for leaks.
4. Adjust the flowmeter until desired pressure is obtained. Flow of 12 - 14 LPM is required to reach CPAP pressure of 8.5 - 10 cm H2O.

DIRECTIONS FOR PROVIDING BILEVEL:
Ensure device is set in BiLevel mode by rotating the Green switch to the BiLevel setting

1. Connect O2 tubing nipple to gas source. Turn on gas source.
2. Secure the face mask snugly to patient’s face using head harness.
3. Slowly increase gas flow to reach approximately 8 cm H2O IPAP. This is the minimum IPAP pressure required for device to function properly in the BiLevel mode. Check mask fit to patient and device connections for leaks.
 a. Adjust the flowmeter until desired IPAP pressure is obtained. Flow of 17 LPM is required to reach maximum IPAP pressure of 12 - 13 cm H2O.
 b. To decrease EPAP pressure rotate EPAP knob counterclockwise. To increase EPAP pressure rotate EPAP knob clockwise.
4. Effective mask seal is required for device to shift into EPAP mode from IPAP mode

Attachments
Return Policy

Shipping Terms:

 

Orders will be shipped via UPS Standard Ground unless other handling is requested or deemed more economical. Freight will be prepaid and added to the invoice. QuadMed will pay standard ground shipment costs on all orders over $150.00  for any shipment delivered in the U.S. except for Alaska and Hawaii.

 

Any orders under $150.00 will be charged a $14.95 handling fee for any shipment delivered in the U.S. except for Alaska and Hawaii. Orders going to Alaska or Hawaii actual shipping rates apply.  For all resellers, freight will be prepaid and added to the invoice. Shipments will be made to business addresses only.

 

 

International Orders:

 

There is a $500.00 minimum for orders placed for delivery outside of the United States. International orders must prepay via wire transfer.

 

 

Returned Goods:

 

Written authorization must be obtained prior to returning merchandise. All returns should be sent within 30 days in resalable condition. Returns are subject to a 20% restocking charge. Merchandise held longer than 90 days, or custom items, are not returnable. All returned items must be sent prepaid.


All returns must be accompanied by an RMA. If you need to return an item or items, please contact Customer Service at 800-933-7334 or email us at [email protected] to obtain an RMA.

TEASoftware